Adjusting the White Balance

Adjust the white balance according to the color temperature of the lighting. You can select the adjustment mode according to the shooting conditions.

As the color of the light (color temperature) varies according to the light source, it is necessary to readjust the white balance when the main light source illuminating the subject changes.

GY-HM200_WhiteBalance

Automatic White Balance Mode (FAW: Fulltime Auto White balance)

Press and hold the [FULL AUTO] button to set Full Auto mode to off.
Assign “FAW” (Full Auto White Balance) to one of the three [WHT.BAL B/A/PRST] switches.

You can set the Full Auto White Balance feature to either “A”, “B”, or “PRST” in [Camera Function] arrowR [FAW].

If the position assigned with “FAW” is selected using the [WHT BAL B/A/PRST] switch, the Automatic White Balance mode is enabled and an appropriate white balance is automatically adjusted according to the color temperature of the lighting on the subject.

Caution

The accuracy of [FAW] is inferior to that of [AWB] (Auto White Balance).

When the power of the camera recorder is turned on with the [FAW] mode selected, it takes about 15 seconds for the colors to stabilize.

Memo

Pressing and holding the [FULL AUTO] button to enter the Full Auto mode also activates the Automatic White Balance mode. In this case, the Iris, Gain and Shutter also enter into Auto mode forcibly.

Switching of the white balance with the [WHT.BAL B/A/PRST] switch is disabled in the Full Auto mode.

When [Main Menu] arrowR [Camera Function] arrowR [User Switch Set] arrowR [AE/FAW Lock] is set to “AE/FAW” or “FAW”, the white balance when the user button that is assigned with [AE/FAW Lock] is pressed can be fixed while in the Automatic White Balance mode.

If [White Balance] is assigned to the user button, pressing the assigned user button will display the FAW Paint Adjustment screen.

FAW Paint Adjustment

You can fine-adjust the white balance that was automatically adjusted.

Select [Main Menu] arrowR [Camera Process] arrowR [White Balance] arrowR [FAW Paint] and press the Set button ( REC button ).

The FAW Paint Adjustment screen appears.

FAWPaint_01_890
Adjust the R and B values.

Use the cross-shaped button ( U_botton D_botton ) to adjust R value and ( L_botton R_botton ) to adjust B value.

WhitePaint_890
Press the Set button ( REC button ).

Returns to the [White Balance] screen.

FAWPaint_02_890

Manual White Balance Mode (Manual Switching)

Press and hold the [FULL AUTO] button to set Full Auto mode to off.

Use the [WHT.BAL B/A/PRST] switch to select “PRST” (preset mode), “A” (memory A mode), or “B” (memory B mode).

Memo

You can set the Full Auto White Balance feature to either [A], [B], or [PRST] in [Camera Function] arrowR [FAW].

The FAW (Full Time Auto White Balance) mode makes automatic adjustments by sampling the color temperature of the video to obtain the most appropriate white balance level.

Preset Mode (PRST)

Two different color temperature settings are registered on this camera recorder. You can switch between them using the [AWB/9] button.

You can also use the user button assigned with [AWB] instead of the [AWB/9] button.

Default setting:

[Preset Temp.]:

3200K

[Alternative Temp.]:

5600K

Set the [WHT.BAL B/A/PRST] switch to “PRST”.
Press the [AWB/9] button.

Press the [AWB/9] button to switch to a different color temperature.
(“Preset Temp.” arrowLR “Alternative Temp.”)

Setting the [Preset Temp.] or [Alternative Temp.] Values

You can change both the color temperature settings in the Preset mode in the menu.

Open the [Preset Temp.] or [Alternative Temp.] menu.

Select [Main Menu] arrowR [Camera Process] arrowR [White Balance] arrowR [Preset Temp.] and [Alternative Temp.], and press the Set button ( REC button ).

The Color Temperature setting screen appears.

WhiteBalance
Select the color temperature.

When selecting from a setting value (Color Temperature Selection screen), use the cross-shaped button ( U_botton D_botton ) to select the color temperature.
[Setting Values: 7500K, 6500K, 5600K, 5200K, 4800K, 4200K, 3200K, 3000K, 2800K]

To select detailed values (Color Temperature Detailed Selection screen)

Press the cross-shaped button ( R_botton ) to display the Color Temperature Detailed Selection screen.

Use the cross-shaped button ( U_botton D_botton ) to select a color temperature.
[Setting Values: 2300K to 15000K (in 100K increments)]

Memo

Use the cross-shaped button ( R_botton ) to switch between the Color Temperature Selection screen and the Color Temperature Detailed Selection screen.

If [White Balance] is assigned to the user button, pressing the assigned user button will display the Color Temperature Selection screen.

Memory A Mode (A), Memory B Mode (B)

Set to the white balance saved in Memory A or Memory B.

When the [WHT.BAL B/A/PRST] switch is set to “A” or “B”, press the [AWB/9] button to execute Auto White Balance. The white balance will be automatically adjusted and the adjusted value will be saved in Memory A or Memory B.

You can also use the user button assigned with [AWB] instead of the [AWB/9] button.

Prepare the camera recorder.
Set the [POWER ON/OFF] switch to “ON”.
Press and hold the [FULL AUTO] button to set to “OFF”.
Press the [IRIS A/M] button to set to the Auto mode.
Set the [ND FILTER] switch according to the lighting.
Set the [WHT.BAL B/A/PRST] switch to “A” or “B”.
Locate a place with similar lighting conditions as the object to be shot, place a white object near the center of the screen and zoom in to fill the screen with white.
Press the [AWB/9] button.

The white detection frame appears when Auto White Balance is activated. Fill the frame with white completely.

While Auto White Balance is starting up, “A<  AWB  >” or “B<  AWB  >” appears on the screen. ( AWB mark appears blinking)

After the correct white balance is obtained, an estimated value of the current color temperature is displayed.

GY-HM200_AutoWite_Ope02
Caution

Do not use highly reflective objects, such as metals. Doing so may result in improper white balance adjustment.

The Auto White Balance function cannot provide optimum white balance with an object outside the adjustment range, for example when it contains only a single color or not enough white color.

Error Message

If the Auto White Balance adjustment is not correctly completed, one of the following messages will appear for about 3 seconds.

Message

Status

Auto White * NG: Object
(*A or B)

Displayed when there is not enough white color on the object, or when the color temperature is not suitable.

Use another white object and adjust the white balance again.

Auto White * Error: Low Light
(*A or B)

Displayed when the lighting is dark. Increase the lighting and adjust the white balance again.

Auto White * Error: Over Light
(*A or B)

Excessive illumination.

Displayed when the lighting is too bright. Decrease the lighting and adjust the white balance again.

White Paint Adjustment

You can fine-tune the white balance saved in Memory A or Memory B.

Select [Main Menu] arrowR [Camera Process] arrowR [White Balance] arrowR [AWB Paint] and press the Set button ( REC button ).

The White Paint Adjustment screen appears.

WhitePaint00_890
Adjust the R and B values.

Use the cross-shaped button ( U_botton D_botton ) to adjust R value and ( L_botton R_botton ) to adjust B value.

WhitePaint_890
Press the Set button ( REC button ).

Returns to the [White Balance] screen.

WhitePaint02_890
Memo

Executing Auto White Balance will usually clear the White Paint Adjustment value. But when [Main Menu] arrowR [Camera Process] arrowR [White Balance] arrowR [Clear Paint After AWB] is set to “Off”, values will not be cleared even when Auto White Balance is executed.

If [White Balance] is assigned to the user button, pressing the assigned user button will display the AWB Paint Adjustment screen.