Command Format

The command between this unit and the computer consists of “Header”, “Unit ID”, “Command”, “Data” and “End”.

Header (1 byte), Unit ID (2 bytes), Command (2 bytes), Data (n bytes), End (1 byte)

Header

This binary code indicates the start of communication.

Binary Code

Type

Description

21

Operating command

PC arrow This unit

3F

Reference command

PC arrow This unit

40

Response command

This unit arrow PC

06

ACK

This unit arrow PC (returns to PC after the command is accepted without error)

Unit ID

This is a code that specifies the unit. The binary code is fixed at “8901”.

Command and data

Operating command and data (binary code)

Command

Type

Description

0000

Connection check

Check whether communication is enabled between this unit and the PC during standby.

5057

Power supply

During standby
31: Turns on the power
When power is on
30: Turns off the power (Standby mode)

4950

Input

When power is on
36: HDMI 1
37: HDMI 2

5243

Remote control

Sends the same code as the supplied remote control.

Remote Control Code

Reference command and data (binary code)

Command

Type

Description

5057

Power supply

During standby or when power is on
30: Standby mode
31: When power is on
32: In the Cool-down mode
34: When error occurs on this unit

4950

Input

When power is on
36: HDMI 1
37: HDMI 2

End

This code indicates the end of communication. The binary code is fixed at “0A”.