Be sure to put on protective glasses to protect your eyes from falling objects when mounting the camera.
Installation and Connection Preparations (VN-H657WPU)
TOPSetting Up the Wall
Make a hole (Φ45 mm) for the connecting cables to pass through.
Check the strength of the wall. A less firm wall may cause the unit to fall.
Install 4 anchor bolts (M8 35 mm and above) to mount the camera.
Install the anchor bolt to mount the fall prevention wire 30 mm below the center of the upper two anchor bolts that are used to mount the camera.
Pull the power cable, LAN cable and alarm signal cable from the wall.
Setting Up the Camera
Loosen the screws (x4) and remove the dome cover from the camera.
When installing the heater at an unrequired location, turn off the ON/OFF switch of the heater.
Be sure to insert the provided silica gels in the position as shown in the diagram.
After inserting the silica gels, check that they are not touching the heater.
Turn the clamp until the silica gels are secured, followed by tightening the screw.
During reconnection or re-installation after repair or maintenance, make sure to replace the silica gels with new ones.
Consult your dealer on the replacement procedures. Use the silica gel with a service part number of LW40500-001A for the part to be replaced.
If silica gel is not inserted, the camera lens and dome cover may turn foggy, and the camera image may not turn out clear.
When installing on a rainy day, ensure that raindrops do not enter the interior.
Use the screws (x4) to mount the dome cover to the camera. When installing the dome cover, make use of the three catches and the center mark of the cover as a guide. Install such that the central mark appears above the JVC mark of the camera.
Check that there is no dirt or dust inside the dome cover before mounting.
When installing on a rainy day, ensure that raindrops do not enter the interior.
When mounting the dome cover, temporarily secure the four screws and then tighten.
As a guide, tighten the screws to 0.5 N·m to 1 N·m (5 kgf·cm to 10 kgf·cm). If the screws are insufficiently tightened, the dome cover may fog due to moisture penetration.
Remove the cap on the arm of the camera.
Pull out the cables (except the fall prevention wire) of the camera from the cable connection hole.